Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Dosimetric comparison of different intensity-modulated radiotherapy techniques for whole-breast irradiation of right-breast cancer (2023) |
Auteurs : | Y.-Q. Song ; J. Hong ; J.-Y. Wang ; J. Peng ; J.-H. Han ; H.-L. Luo |
Type de document : | Article |
Dans : | Cancer/Radiothérapie (Vol. 27, n° 1, Février 2023) |
Article en page(s) : | p. 11-16 |
Note générale : | https://doi.org/10.1016/j.canrad.2022.04.009 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Dose de radiation ; Exposition aux rayonnements ; Radiothérapie ; Radiothérapie conformationnelle avec modulation d'intensité (RCMI) ; Tumeurs du sein ; Tumorectomie |
Résumé : |
Purpose : This study compared the dosimetric parameters of field-in-field forward intensity-modulated radiotherapy (FIF-IMRT) and fixed-field inversely optimized intensity-modulated radiotherapy (FFIO-IMRT) for the whole-breast irradiation of patients undergoing right-breast lumpectomy.
Material and methods : A total of 30 patients with pT1-2N0M0 right-breast invasive ductal carcinoma were enrolled in this study. Two different treatment plans, i.e., FIF-IMRT and FFIO-IMRT, were designed for each patient. The dosimetric parameters of the two treatment plans were compared including ipsilateral lung and heart, conformity index (CI), and the homogeneity index (HI) of the planning target volume (PTV). Results : Fixed-field inversely optimized intensity-modulated radiotherapy was found to significantly improve CI (83.302% vs. 60.146%) and HI (11.837% vs. 19.280%), and significantly reduced V25 (18.038% vs. 19.653%) and V30 (15.790% vs. 18.492%) of the ipsilateral lung. It also significantly increased V5 (69.791% vs. 32.615%) of the ipsilateral lung and V5 (61.579% vs. 3.829%), V10 (14.130% vs. 0.381%), V20 (1.843% vs. 0.051%), and Dmean (5.211Gy vs. 1.870Gy) of the heart. Conclusion : Regardless of improving the conformity and homogeneity of PTV and reducing the ipsilateral lung irradiation volume at high doses, FFIO-IMRT significantly raised the ipsilateral lung irradiated volume at low doses, as well as the irradiation volume and mean radiation doses to the heart. This limits its use in patients with early-stage right breast cancer. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S127832182200097X |