Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Reference values, minimum repetitions for stable measures, and test-retest reliability in the torsion and conventional cervical joint position sense tests in asymptomatic individuals (2022) |
Auteurs : | Ibai López-de-Uralde-Villanueva ; Adriana García-Alonso ; David García-Herranz ; César Fernández-de-las-Peñas ; Gustavo Plaza-Manzano ; Tamara Del Corral ; Julia Treleaven |
Type de document : | Article |
Dans : | Musculoskeletal Science and Practice (Vol. 62, December 2022) |
Article en page(s) : | 102681 |
Note générale : | https://doi.org/10.1016/j.msksp.2022.102681 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Anomalie de torsion ; Cou ; Proprioception ; Reproductibilité des résultats ; Vertèbres cervicales |
Résumé : | Objective To determine reference values, including the appropriate number of repetitions, and test-retest reliability of the torsion and conventional cervical joint position sense (JPS) tests. Methods Phase 1) Cross-sectional design to determine reference values and the appropriate number of repetitions; Phase 2) repeated-measures concordance design (test-retest reliability). Sixty-eight healthy participants performed 10 repetitions of randomized rotation left and right for both cervical JPS tests using a laser projected onto a target. Thirty participants returned for the same evaluation process one week later. Results The age-stratified reference values for the torsion JPS test showed greater absolute error as age increased. Stable levels of performance were obtained with 6?7 repetitions for both tests. Moderate to good reliability was found with 7 or more repetitions for left rotation [Torsion JPS test, Intraclass Correlation Coefficient (ICC; 95% CI) = 0.85 (0.68?0.93); Conventional JPS test, ICC = 0.78 (0.53?0.89)], and 6?7 or more repetitions for right rotation [Torsion JPS test, 6 repetitions, ICC = 0.79 (0.56?0.90); Conventional JPS test, 7 repetitions, ICC = 0.82 (0.61?0.91)]. Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) stabilized at 7 repetitions in both tests [Torsion JPS test (SEM ? 1.0°; MDC90 ? 2.4°; MDC95 ? 2.9°); Conventional JPS test (SEM ? 1.2°; MDC90 ? 2.8°; MDC95 ? 3.3°)]. Conclusions The reference values generated for the torsion JPS test may help identify the presence of impairments cervical proprioception. At least 7 repetitions optimize stability, reliability and responsiveness in the torsion and conventional cervical JPS tests. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S2468781222001825 |