Titre : | Comparison of Ischial Containment and Subischial Sockets Effect on Gait Biomechanics in People With Transfemoral Amputation: A Randomized Crossover Trial (2022) |
Auteurs : | Stefania Fatone ; Rebecca Stine ; Ryan Caldwell ; John Angelico ; Steven Gard ; Michael Oros ; Matthew J. Major |
Type de document : | Article |
Dans : | Archives of Physical Medicine and Rehabilitation (Vol. 103, n° 8, 2022) |
Article en page(s) : | p. 1515-1523 |
Note générale : | https://doi.org/10.1016/j.apmr.2022.02.013 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Analyse de démarche ; Membre inférieur ; Membres artificiels ; Réadaptation ; Résultat thérapeutique |
Résumé : |
Objective
To compare gait biomechanics of the Northwestern University Flexible Sub-Ischial Vacuum (NU-FlexSIV) Socket to the ischial containment (IC) socket. Design Randomized crossover trial with 2, 7-week periods. Setting Private prosthetic clinics and university research laboratory. Participants A total of 30 enrolled (n=30); 25 participants completed the study with full (n=18) or partial data (n=7). Interventions Two custom-fabricated sockets (IC and NU-FlexSIV), worn full-time for 7 weeks, with testing at 1, 4, and 7 weeks after socket delivery. Main Outcome Measures Gait analyses were conducted at 1, 4, and 7 weeks post socket delivery. Differences between sockets in selected gait variables related to hip motion and coronal plane socket stability were assessed. Results For participants with data for both sockets at week 7 (n=19), there were no significant differences in any gait variables between sockets at self-selected normal walking speed. However, when all participants and all study time points were assessed (n=25), there was a significant main effect of socket (P=.013), with prosthetic side sagittal plane hip range of motion being significantly greater for the NU-FlexSIV Socket at self-selected normal walking speed. There were no other significant effects. Conclusions The results suggest that, compared to the IC socket, the NU-FlexSIV Socket did not alter gait biomechanics related to hip motion and coronal plane socket stability in people with unilateral transfemoral amputation. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S0003999322002696#! |