Titre : | PROMIS Physical Function Short Forms Display Item- and Scale-Level Characteristics at Least as Good as the Roland Morris Disability Questionnaire in Patients With Chronic Low Back Pain (2020) |
Auteurs : | Alessandro Chiarotto ; Leo D. Roorda ; Martine H. Crins |
Type de document : | Article |
Dans : | Archives of Physical Medicine and Rehabilitation (Vol. 101, n° 2, 2020) |
Article en page(s) : | p. 297-308 |
Note générale : | https://doi.org/10.1016/j.apmr.2019.09.018 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Lombalgie ; Réadaptation |
Résumé : |
To compare dimensionality, item-level characteristics, scale-level reliability, and construct validity of PROMIS Physical Function short forms (PROMIS-PF) and 24-item Roland Morris Disability Questionnaire (RMDQ-24) in patients with chronic low back pain (LBP).
Design Cross-sectional study. Setting Secondary care center for rehabilitation and rheumatology. Participants Patients with nonspecific LBP ≥3 months (N=768). Mean age was 49±13 years, 77% were female, and 54% displayed pain for more than 5 years. Interventions Not applicable. Main Outcome Measures Dutch versions of the 4-, 6-, 8-, 10-, and 20-item PROMIS-PF and of the RMDQ-24. Results PROMIS-PF-6, PROMIS-PF-8, and RMDQ-24 exhibited sufficient unidimensionality (confirmatory factor analysis: comparative fit index>0.950, Tucker-Lewis index>0.950, root means square error of approximation.001). Two-parameter item response theory models found 2 items with low discrimination for RMDQ-24. All other instruments had adequate fit statistics and item parameters. PROMIS-PF-20 displayed the best scale-level reliability. Construct validity was sufficient for all instruments as all hypotheses on expected correlations with other instruments and differences between relevant subgroups were met. Conclusions PROMIS-PF-6, PROMIS-PF-8, and RMDQ-24 exhibited better unidimensionality, whereas PROMIS-PF-4, PROMIS-PF-6, PROMIS-PF-8, and PROMIS-PF-10 showed superior item-level characteristics. PROMIS-PF-20 was the instrument with the best scale-level reliability. This study warrants assessment of other measurement properties of PROMIS-PF short forms in comparison with disease-specific physical functioning instruments in LBP. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S0003999319313620 |