Titre : | Establishing the reliability of a novel battery of range of motion tests to enable evidence-based classification in Para Swimming (2018) |
Auteurs : | Vaughan P. Nicholson ; Jemima G. Spathis ; Luke W. Hogarth ; et al. |
Type de document : | Article |
Dans : | Physical therapy in sport (Vol. 32, July 2018) |
Article en page(s) : | p. 34-41 |
Note générale : | https://doi.org/10.1016/j.ptsp.2018.04.021 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Efficacité ; Epaule ; Hanche ; Natation ; Personnes handicapées |
Mots-clés: | Inclinomètre ; Classification basée sur les preuves |
Résumé : |
Objectives
To evaluate the reliability of swimming-specific range of movement tests developed in order to permit evidenced-based classification in the sport of para swimming. Design Test-retest intra- and inter-examiner reliability. Setting International Swimming training camps and university exercise science departments. Participants 42 non-disabled participants (mean age 23.2 years) and 24 Para swimmers (mean age 28.5 years). Main outcome measures Intra- and inter-examiner reliability of a battery of novel active range of motion tests. Results Good to excellent intra-examiner reliability was found for the majority (32/34) of tests in non-disabled participants (ICC = 0.850.98). SEM values ranged from 1.18° to 6.11°. Similarly, good to excellent inter-examiner reliability was found for the majority (35/42) of tests in non-disabled participants (ICC = 0.850.98). SEM values range from 0.73° to 6.52°. Para swimmers exhibited significantly reduced range of motion compared to non-disabled participants. Conclusions The large majority of ROM tests included in this novel battery were reliable both within and between examiners in non-disabled participants. The tests were found to differentiate between non-disabled participants and Para swimmers with hypertonia or impaired muscle power. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S1466853X17307009 |