Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Functional Electrical Stimulation for Foot Drop in Multiple Sclerosis: A Systematic Review and Meta-Analysis of the Effect on Gait Speed (2017) |
Auteurs : | Linda Miller ; Angus McFadyen ; Anna C. Lord |
Type de document : | Article |
Dans : | Archives of Physical Medicine and Rehabilitation (2017/7, 2017) |
Article en page(s) : | pp. 14351452 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Rééducation et réadaptation ; Revue de la littérature ; Sclérose en plaques |
Mots-clés: | Electric stimulation ; Stimulation électrique ; Gait disorders ; neurologic ; Troubles neurologiques de la marche ; Multiple sclerosis ; Review ; Walking ; Marche à pied |
Résumé : |
Objective To review the efficacy of functional electrical stimulation (FES) used for foot drop in people with multiple sclerosis (pwMS) on gait speed in short and long walking performance tests. Data Sources Five databases (Cochrane Library, CINAHL, Embase, MEDLINE, and PubMed) and reference lists were searched. Study Selection Studies of both observational and experimental design where gait speed data in pwMS could be extracted were included. Data Extraction Data were independently extracted and recorded. Methodologic quality was assessed using the Effective Public Health Practice Project tool. Data Synthesis Nineteen studies (described in 20 articles) recruiting 490 pwMS were identified and rated as moderate or weak, with none gaining a strong rating. All studies rated weak for blinding. Initial and ongoing orthotic and therapeutic effects were assessed regarding the effect of FES on gait speed in short and long walking tests. Meta-analyses of the short walk tests revealed a significant initial orthotic effect (t=2.14, P=.016), with a mean increase in gait speed of .05m/s, and ongoing orthotic effect (t=2.81, P=.003), with a mean increase of .08m/s. There were no initial or ongoing effects on gait speed in long walk tests and no therapeutic effect on gait speed in either short or long walk tests. Conclusions FES used for foot drop has a positive initial and ongoing effect on gait speed in short walking tests. Further fully powered randomized controlled trials comparing FES with alternative treatments are required. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S0003999317300035 |