Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Simultaneous dual-isotope 123I/99mTc acquisition using CZT-based cameras: Toward a one-stop-shop SPECT in heart failure patients (2018) |
Titre original: | Acquisition simultanée double-isotope (123I:99Tc) avec les gamma-caméras à semi-conducteur CZT: vers un examen tout-en-un chez les patients insuffisants cardiaques |
Auteurs : | T. Blaire ; A. Bailliez ; F. Ben Bouallegue ; et al. |
Type de document : | Article |
Dans : | Médecine nucléaire (Vol. 42, n° 1, 2018) |
Article en page(s) : | 3-8 |
Langues: | Français |
Descripteurs : |
HE Vinci Caméras à rayons gamma ; Insuffisance cardiaque ; Radio-isotopes |
Résumé : | The CZT-cameras (DNM 530c and DSPECT) have only recently been introduced, and the impact of the increased energy resolution remains unknown. This paper summarizes the evidence on the assessment of: (i) the left ventricular function, (ii) the 123I/99mTc mismatch, and (iii) the heart-to-mediastinum ratio (HMR) of 123I-metaiodobenzylguanidine (MIBG) uptake under dual-isotope conditions (99mTc and 123I) using cadmium-zinc-telluride (CZT) technology. The diagnostic accuracy of CZT cameras for myocardial sympathetic innervation imaging, left ventricular function and perfusion assessment using perfusion-gated SPECT have only been established in a few studies, under single-isotope conditions. Limited evidence is available regarding simultaneous dual-isotope acquisition using CZT-cameras. However, recently reported data have shown that CZT cameras allow, in dual-isotope (123I and 99mTc) acquisitions and under routine conditions: (i) a simultaneous and accurate segmental study of myocardial innervation and perfusion (match and mismatch), (ii) the ventricular function assessment (EDV, ESV and LVEF), and (iii) the determination of the late HMR of cardiac 123I-MIBG uptake in patients with heart failure. However, this latter should be performed using transaxial reconstructed images and a linear correction based on phantom data acquisitions. |
Disponible en ligne : | Oui/Non |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.em-premium.com/revue/mednuc/42/1 |
Exemplaires (1)
Cote | Support | Localisation | Section | Disponibilité |
---|---|---|---|---|
REV | Périodique papier | Woluwe | Espace revues | Consultation sur place uniquement Exclu du prêt |