Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Reliability and criterion validity of handheld dynamometry for measuring trunk muscle strength in people with and without chronic non-specific low back pain (2023) |
Auteurs : | Shouq Althobaiti ; Deborah Falla |
Type de document : | Article |
Dans : | Musculoskeletal Science and Practice (Vol. 66, August 2023) |
Article en page(s) : | 102799 |
Langues: | Anglais |
Mots-clés: | Handheld dynamometer ; Low back pain ; Trunk muscle strength ; Psychometric properties |
Résumé : | Background Evaluating trunk strength is an important aspect of the physical examination of people with low back pain (LBP). Thus, reliable, valid, and easily applied measurement tools are needed to quantify trunk muscle strength and monitor changes in response to interventions. Objectives To determine within-day and between-day test re-test reliability and criterion validity of a handheld dynamometer (HHD) to evaluate maximum isometric trunk strength in people with chronic LBP and asymptomatic individuals. Design Reliability and criterion validity study. Methods Twenty adult participants with chronic, non-specific LBP and 35 asymptomatic individuals participated. Isometric trunk flexion, extension, and rotation strength were evaluated with the HHD (Active force 2) and the within-day and between-day reliability were determined with intraclass correlation coefficients (ICC2,1) and the standard error of the measurements (SEM), minimal detectable change (MDC), and the limits of agreement (LOA) using Bland-Altman plots. Criterion validity was evaluated using Pearson correlation coefficients to compare HHD measurements to isokinetic dynamometry for both isometric trunk flexion and extension strength. Results Good to excellent within-day and between-day reliability was observed for people with LBP and asymptomatic individuals with (ICC2,1) of 0.73?0.93 and 0.62?0.92 respectively. A moderate to strong correlation was found between measurements with the HHD and the isokinetic dynamometer with a correlation of r = 0.68?0.78 and r = 0.56?0.59 for people with LBP and asymptomatic participants respectively. Conclusion A HHD is a reliable, valid, and clinically applicable tool for the measurement of trunk strength in adults with and without chronic LBP. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S246878122300084X |