Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Evaluation of Two Spectro-Temporal Ripple Tests and Their Relation to the Matrix Speech-in-Noise Sentence Test in Cochlear Implant Recipients (2023) |
Auteurs : | Nicolaas R. A. van Groesen ; Jeroen J. Briaire ; Johan H.M. Frijns |
Type de document : | Article |
Dans : | Ear and hearing (Vol. 44, n°5, September- October 2023) |
Article en page(s) : | p. 1221-1228 |
Note générale : | DOI: 10.1097/AUD.0000000000001365 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Analyse spectrale ; Implants cochléaires ; Ondulation spectrale ; Perception de la parole |
Résumé : |
Objectives: Spectro-temporal ripple tests are commonly used in cochlear implant (CI) research as language-independent indicators of speech recognition (in noise) or as stand-alone tests. Test-retest reliability of these tests has been scarcely documented. We evaluated the test-retest reliability of spectral-temporally modulated ripple test (SMRT) and spectro-temporal ripple for investigating processor effectiveness (STRIPES) and correlated their findings to the Dutch/Flemish Matrix speech-in-noise sentence test (MST) in CI recipients. This is the first time spectro-temporal ripple tests are correlated to an MST.
Design: Take-home data from 15 participants over 2 test days were analyzed. Participants were fitted with their clinical speech encoding strategy (Advanced Bionics HiRes Optima) or a 14-channel non-steered monopolar strategy. Test-retest reliability was calculated through intraclass correlation coefficients and visualized through Bland Altman plots. Association of the spectro-temporal ripple tests with the MST was evaluated through linear regression analysis. Results: The SMRT and STRIPES possessed a similarly rated "good" test-retest reliability (SMRT: ICC = 0.81, confidence interval = 0.67 to 0.92; STRIPES: ICC = 0.87, confidence interval = 0.76 to 0.95) and an identical linear relationship to speech recognition in noise (SMRT: R2 = 0.28, p = 0.04; STRIPES: R2 = 0.28, p = 0.04). Both tests revealed a stable variability between session 1 and 2 outcome scores on Bland Altman plots. Conclusion: On the basis of our data, both spectro-temporal ripple tests possess similar test-retest reliability and a similar association with the MST. The SMRT and STRIPES can therefore both be used equally well as a quick indicator of across-listener differences in speech recognition in noise in CI recipients. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&D=yrovftz2&AN=00003446-202309000-00027 |