Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Intra and interrater reliability for lower limb flexibility assessment using photogrammetry (2023) |
Auteurs : | Carolina Holz Nonnenmacher ; Daniela de Estéfani ; Inaihá Laureano Benincá ; Maiara Petri da Silveira ; Guilherme S. Nunes ; Alessandro Haupenthal |
Type de document : | Article |
Dans : | Journal of Bodywork and Movement Therapies (Vol. 35, Juillet 2023) |
Article en page(s) : | p. 364-370 |
Note générale : | https://doi.org/10.1016/j.jbmt.2023.04.078 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Amplitude articulaire ; Biais de l'observateur ; Flexibilité (corps humain) ; Reproductibilité des résultats |
Résumé : | Introduction Photogrammetry represents an advancement in the flexibility evaluation, and although it was highly explored for postural assessment, there is a scarcity of studies analyzing lower limb angular measurements using it. The purpose of this study is to verify the reliability of intrarater and interrarater photogrammetry in assessing lower limb flexibility. Methods This was a randomized cross-sectional observational study with test-retest design and a two-day interval. Thirty healthy, physically active adults were included. Three novice raters assessed the participants through flexibility tests of iliopsoas, hamstring, quadriceps and gastrocnemius on two occasions, and independently analyzed the captured images to establish reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated. Results Intrarater reliability was excellent for iliopsoas (ICC = 0.96; SEM = 1.4; MDC = 3.8), hamstring (ICC = 0.99; SEM = 1.1; MDC = 3.1), quadriceps (ICC = 0.99; SEM = 0.8; MDC = 2.3) and gastrocnemius (ICC = 0.98; SEM = 0.9; MDC = 2.5). Interrater reliability was excellent for iliopsoas (ICC = 0.94; SEM = 1.7; MDC = 4.6) and gastrocnemius (ICC = 0.91; SEM = 2.1; MDC = 5.8), but good for hamstring (ICC = 0.90; SEM = 2.8; MDC = 7.9) and quadriceps (ICC = 0.85; SEM = 3.0; MDC = 8.3). Conclusions The excellent intrarater and good to excellent interrater reliability suggest that photogrammetry assessment of lower limb flexibility by novice raters is reliable. However, clinicians should consider the higher threshold of range of motion change necessary to outweigh measurement error due to interrater variability. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S1360859223000931 |