Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Functional results with active middle ear implant or semi-implantable bone conduction device in patients with comparable hearing loss (2022) |
Auteurs : | Jennifer L. Spiegel ; Bernhard G. Weiss ; Mattis Bertlich ; Ivelina Stoycheva ; Martin Canis ; Friedrich Ihler |
Type de document : | Article |
Dans : | International Journal of Audiology IJA (vol. 61, no. 10, octobre 2022) |
Article en page(s) : | p. 859-867 |
Note générale : | https://doi.org/10.1080/14992027.2021.1966704 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Aides auditives ; Conduction osseuse ; Oreille moyenne ; Perception de la parole ; Prothèse ossiculaire ; Troubles de l'audition |
Résumé : |
Objective
In patients with conductive (CHL) or mixed hearing loss (MHL), hearing rehabilitation with an implantable hearing system, active middle ear implant (AMEI) or a semi-implantable bone-conduction device (SIBCD), is an option when conventional hearing aids are insufficient, or patients are unable to wear them. Design Retrospective analysis of 20 consecutive patients (24 implants) with a comparison of demographic characteristics and audiometric results (air-bone gap = ABG, effective hearing gain = EHG, functional hearing gain = FHG, Freiburg Monosyllabic Test in quiet, Oldenburg Sentence Test in noise = OLSA). Study sample Patients, eligible for both devices, who received either AMEI or SIBCD due to CHL or MHL. Results Analysis showed no significant differences in post-operative functional hearing results between the group of AMEI vs. SIBCD (ABG-reduction: 31.6 ± 12.4 dB HL vs. 28.0 ± 11.8 dB HL; p = 0.702; EHG: −1.6 ± 7.7 dB HL vs. −1.2 ± 4.2 dB HL; p = 0.090; FHG: 33.4 ± 12.6 dB HL vs. 26.1 ± 11.7 dB HL; p = 0.192; Freiburg: 83.0 ± 15.6% vs. 83.6 ± 14.2%; Freiburg-improvement: 57.7 ± 26.8% vs. 68.2 ± 19.7%; p = 0.294; OLSA: −2.7 ± 3.0 SNR vs. −1.4 ± 3.6 SNR; OLSA-improvement: 2.6 ± 2.1 dB vs. 3.7 ± 2.8 dB; p = 0.323). Four patients had the AMEI explanted due to insufficient functioning and later received a SIBCD. Conclusions Due to more challenging anatomical conditions, a surgical technique for the AMEI is more complex. However, functional results are comparable to the SIBCD. Therefore, proper patient counselling and cautious choice of the device are mandated before surgery. |
Accès : | Contactez la bibliothèque d'Ixelles si le lien vers la ressource électronique ne fonctionne pas |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url= |