Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Safety and Efficacy of Implantation of the Bonebridge Active Transcutaneous Bone-Conduction Device Using Implant Lifts (2021) |
Auteurs : | Faris F. Brkic ; Dominik Riss ; Christoph Arnoldner ; Rudolfs Liepins ; Wolfgang Gstöttner ; Wolf-Dieter Baumgartner ; Erich Vyskocil |
Type de document : | Article |
Dans : | Journal of the American Academy of Audiology (JAAA) (Vol. 32, n° 5, May 2021) |
Article en page(s) : | p. 290-294 |
Note générale : | DOI: 10.1055/s-0041-1723038 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Complications postopératoires ; Comportement de réduction des risques ; Implant à conduction osseuse ; Prothèse auditive implantable |
Mots-clés: | Implant lifts |
Résumé : |
Background
Implant lifts were recently introduced to facilitate implantation of the Bonebridge and to reduce the risk of uncovering the sigmoid sinus and/or dura. Purpose The current study analyzed medical, technical, and audiological outcomes of implantation with the Bonebridge implant using lifts. Research Design This was a retrospective study on all consecutive patients implanted with a bone-conduction hearing implant at a tertiary medical referral center between March 2012 and October 2018. Outcome measures were complications, explantations, and revisions and the mean time of implant use. Audiological results were assessed as well. Outcomes were evaluated for devices implanted with BCI Lifts and compared with those implanted without lifts. Results In the study period, 13 out of a total of 54 implantations were conducted using one or two 1- to 4-mm BCI Lifts. During the follow-up period, two complications occurred and both in patients implanted without lifts (2/41; 4.9%). All patients in the lifts group were using the implant at the end of observation period. No statistically significant difference was observed in functional hearing gain or word-recognition improvement at 65 dB between two groups. Conclusions The use of BCI Lifts in Bonebridge implantations was not associated with adverse events during the observation period. The clinical follow-up revealed no complications in implantations requiring lifts. Furthermore, the functional hearing gain and the word-recognition improvement did not differ from those of devices implanted without lifts. Data indicate safety and efficacy for Bonebridge implantations |
Disponible en ligne : | Oui/Non |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://medone-comsci.thieme.com/ejournals/2157-3107_2021_05?context=search#/10.1055-s-0041-1723038 |
Exemplaires (1)
Cote | Support | Localisation | Section | Disponibilité |
---|---|---|---|---|
Journal of the American Academy of Audiology. Vol. 32, n° 5 (May 2021) | Périodique papier | Ixelles | Rez | Consultation sur place uniquement Exclu du prêt |