Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Elasticity standard values of the thoracolumbar fascia assessed with acoustic radiation force impulse elastography on healthy volunteers : a cross section study (2021) |
Auteurs : | Jonas Wakker ; Wolfgang Kratzer ; Julian Schmidberger ; Tilmann Graeter |
Type de document : | Article |
Dans : | Journal of Bodywork and Movement Therapies (Vol. 26, April 2021) |
Article en page(s) : | p. 530-537 |
Note générale : | https://doi.org/10.1016/j.jbmt.2020.12.039 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Acoustique ; Fascia ; Femmes ; Fumer ; Hommes ; Imagerie d'élasticité tissulaire ; Imagerie diagnostique ; Reproductibilité des résultats ; Sensibilité et spécificité ; Thérapeutique |
Résumé : |
Introduction
Determining the normal values for acoustic radiation force impulse (ARFI) shear wave elastography of the thoracolumbar fascia (TLF) and define possible factors of influence. Methods We measured the shear wave velocity (SWV) in m/s and the diameter (anterior-posterior) in mm of the TLF bilateral in 267 healthy participants with the Acuson S3000 (Siemens) using the virtual touch image quantification mode (VTIQ). The parameters were tested for correlations with the anthropometric data of the participants, between different age groups and the genders, as well as information obtained from the history, such as smoking and sporting activities. Results We determined a mean SWV of 3.28 ± 0.55 m/s for the left thoracolumbar fascia and 3.44 ± 0.55 m/s for the right. The diameter on the right was 2.7 ± 0.8 mm. On the left, it was 2.7 ± 0.9 mm. Neither body mass index (BMI) nor gender had a significant effect on either of the measured parameters (p > 0.05). The same goes for regular medication, sporting activity or the consumption of alcohol (p > 0.05). The results concerning the effect of smoking and age were inconclusive as they only had a significant influence to either the right or the left side of the TLF but not on the other side. Conclusions We collected the normal value for ARFI shear wave elastography of the TLF in 267 healthy participants. Furthermore, neither gender, BMI, sports activity nor the consumption of alcohol affected the elasticity or the diameter of the thoracolumbar fascia. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://www.sciencedirect.com/science/article/pii/S1360859220301984 |