Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Investigation of an Outcomes-Driven, Computer-Assisted Approach to CI Fitting in Newly Implanted Patients (2021) |
Auteurs : | Teresa A. Zwolan ; Regina Presley ; Laura Chenier ; Barbara Buck |
Type de document : | Article |
Dans : | Ear and hearing (Vol. 42, n°3, Mai- Juin 2021) |
Article en page(s) : | p. 558-564 |
Langues: | Anglais |
Descripteurs : |
HE Vinci FITTING OUTCOME EXPERT (FOX) ; Implants cochléaires ; Intelligence artificielle (IA) |
Résumé : |
Objective: To evaluate the efficacy of outcomes received by newly implanted cochlear implant recipients when an outcomes-driven, computer-assisted approach to cochlear implantation fitting was used. This approach, referred to as "Fitting to Outcome eXpert," or FOX, was developed by Otoconsult in Antwerp, Belgium.
Design: Thirty-one newly implanted subjects participated in a nonrandomized, single-subject, repeated measures design that involved a within-subject comparison of preoperative and postoperative speech recognition scores. Sound processors for all subjects were programmed using the FOX software that utilized the evidence-based results of various psychoacoustic tests to adjust MAP parameters and improve performance. Additionally, mean word and sentence recognition scores obtained by the subjects programmed with FOX were compared to results obtained by newly implanted patients enrolled in the Nucleus CI532 clinical trial whose devices were programmed using traditional methods. Results: Subjects whose sound processors were programmed using FOX obtained a mean 6-month postactivation Consonant Nucleus Consonant word score of 60.2% correct. This represented an improvement of 46% age points when mean preactivation and postactivation scores were compared and represented a statistically significant change in score (p Conclusion: The results of this study support the use of an outcomes-driven, computer-assisted approach to supplement the management of newly implanted cochlear implant recipients. Subjects whose devices were programmed using such an approach demonstrated mean postoperative word in quiet and sentence in noise scores comparable to those obtained by subjects in the Nucleus CI532 clinical trial whose devices were programmed using traditional programming techniques. Use of this approach positively impacted patient care by reducing the number of postoperative visits needed to optimize sound processor programs, simplified patient testing via the use of direct streaming, and ensured that patients received consistent programming of their sound processor, regardless of the location where the programming was performed. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00003446-000000000-00000 |