Titre : | Differences in Word and Phoneme Recognition in Quiet, Sentence Recognition in Noise, and Subjective Outcomes between Manufacturer First-Fit and Hearing Aids Programmed to NAL-NL2 Using Real-Ear Measures (2018) |
Auteurs : | Michael Valente ; Kristi Oeding ; Alison Brockmeyer ; Steven M. Smith ; Dorina Kallogieri |
Type de document : | Article |
Dans : | Journal of the American Academy of Audiology (JAAA) (Vol.29, n° 8, September 2018) |
Article en page(s) : | p. 706-7721 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Mesure acoustique ; Mesure réelle de l'oreille (REM) ; Profil abrégé du bénéfice de l'aide auditive (APHAB) ; Reconnaissance auditive du mot ; Speech spatial and qualities of hearing scale (SSQ)Autres descripteurs Hearing in Noise Test (HINT) ; Reconnaissance des phonemes |
Résumé : |
To examine if significant differences were present in monosyllabic word and phoneme recognition (consonant-nucleus-consonant; CNC) in quiet, sentence recognition in noise (Hearing in Noise Test; HINT), and subjective outcomes using the Abbreviated Profile of Hearing Aid Benefit (APHAB) and the Speech, Spatial and Qualities of Hearing (SSQ) questionnaires between hearing aids fit using one manufacturer’s first-fit and the same hearing aids with a programmed-fit using REM to National Acoustic Laboratories Nonlinear Version 2 (NAL-NL2) prescriptive target.
A double-blind randomized crossover design was used. Throughout the study, one investigator performed all REM whereas a second investigator measured speech recognition in quiet, noise, and scored subjective outcome measures. The hearing aids were fit using the proprietary manufacturer default first-fit and a programmed-fit to NAL-NL2 using real-ear insertion gain measures. The order of the two fittings was randomly assigned and counterbalanced. Participants acclimatized to each setting for four weeks and returned for assessment of performance via the revised CNC word lists, HINT, APHAB, and SSQ for the respective fitting. |
Disponible en ligne : | Oui |
En ligne : | https://login.ezproxy.vinci.be/login?url=https://research.ebsco.com/c/zz54du/search/advanced/publications/9OC?selectedDb=ccmjnh&db=ccm |
Exemplaires (1)
Cote | Support | Localisation | Section | Disponibilité |
---|---|---|---|---|
Journal of the American Academy of Audiology (JAAA). Vol.29, n°8 (September 2018) | Périodique papier | Ixelles | Rez | Consultation sur place uniquement Exclu du prêt |