Login
Communauté Vinci
Extérieur
Si votre nom d'utilisateur ne se termine pas par @vinci.be ou @student.vinci.be, utilisez le formulaire ci-dessous pour accéder à votre compte de lecteur.
Titre : | Comparative Validity of Accelerometer-Based Measures of Physical Activity for People With Multiple Sclerosis (2012) |
Auteurs : | Susan Coote ; Catriona O'dwyer |
Type de document : | Article |
Dans : | Archives of Physical Medicine and Rehabilitation (2012/11, 2012) |
Article en page(s) : | pp. 2022-2028 |
Langues: | Anglais |
Descripteurs : |
HE Vinci Activité motrice ; Rééducation et réadaptation ; Sclérose en plaques |
Mots-clés: | Multiple sclerosis ; Motor Activity ; Reproducibility of Results ; Reproductibilité des résultats |
Résumé : |
"Objective To estimate the criterion validity of accelerometer-based devices as measures of steps and energy expenditure in healthy controls and people with multiple sclerosis (MS) with varying disability levels during everyday activities. Design Cross-sectional study. Setting University research room. Participants People with MS who used at most a stick to walk outdoors (MS-A; n=19), people with MS who used bilateral support for gait (MS-B; n=11), and healthy controls (n=15). Interventions Participants completed 85 minutes of 9 scripted everyday activities. Main Outcome Measures Estimates of metabolic equivalent thresholds (METs) and kilocalories from a portable metabolic system, and steps counted from video of the activities. Step and MET estimates from an integrative accelerometer and from a uniaxial accelerometer, and kilocalorie estimates from the integrative accelerometer. Results The uniaxial accelerometer had >30% error for steps for all groups. MET estimates had an intraclass correlation coefficient (ICC) 20% error. The MET estimates had an ICC of .50 to .65 and 6% to 15% error. Kilocalorie estimates had 2.9% error for controls, 8.16% for MS-A, and 2.56% for MS-B groups. ICCs were all >.67, and mean differences from criterion were Conclusions The agreement between steps and MET estimates from both devices and the criterion was poor, particularly for people with MS. Only the step and MET estimates for the control group for the integrative accelerometer were not significantly different from the criterion. Kilocalorie estimates from the integrative accelerometer using the proprietary algorithms of the device provide the most valid estimate of physical activity during activities of daily living for people with a range of walking disabilities resulting from MS." |
Disponible en ligne : | Oui |
En ligne : | http://www.archives-pmr.org/article/S0003-9993(12)00355-3/abstract |